Activation Code Multisim 14.0.1

четверг 09 апреляadmin

Civilization ii conflicts in civilization scenarios 1

Option Name
Default
Recommendation
Absolute error tolerance
Sets the absolute error tolerance. Default is suitable for most bipolar transistor VLSI circuits.
A
The default is suitable for low-power integrated circuits. If you are simulating power circuits and experiencing convergence problems or slow-run times, increase this value; very tight current tolerances are generally not required for these types of circuits. Values as high as1e-6A range are often acceptable.
Voltage error tolerance
Sets the absolute voltage error tolerance of the program.
V
The default is suitable for low-power integrated circuits. If you are simulating power circuits and experiencing convergence problems or slow-run times, increase this value; very tight voltage tolerances are generally not required for these types of circuits. Values as high as 1e-3V range are often acceptable.
Charge error tolerance
1.0e-14
Do not change.
Relative error tolerance
Sets the relative error tolerance of the simulation, which is the universal accuracy control. The value can significantly affect the convergence of the solution and the simulation speed. Value must be between 1 and 0.
If experiencing non-convergence, loosening the relative tolerance often helps. It is generally not advisable to increase this value above 0.01.
Minimum conductance
Sets the minimum conductance used across junctions in semiconductor devices.
mho
Increasing this may positively improve the convergence of the solution, however, it will also negatively affect simulation accuracy.
Minimum acceptable ratio of pivot
Resets the relative value between the largest column entry in the matrix and an acceptable pivot value. Value must be between 1 and 0.
If experiencing non-convergence, as an attempt of last resort, increase this value. High values (e.g., 0.9) have been found to help convergence.
Minimum acceptable ratio of pivot
Sets the absolute minimum value for a matrix entry to be accepted as a pivot value.
TEMP
Sets the temperature at which the entire circuit will be simulated. Many devices have characteristics that are functions of the operating temperature.
×C
RSHUNT
Inserts a resistance from every analog node to ground. This is to eliminate Singular Matrix errors that result from a lack of DC path to ground and, in some cases, to assist convergence.
W
Usually set to some very high resistance (say 1e+12 W, as lower values can be comparable to actual circuit impedances and affect the accuracy. For high impedance circuits, and circuits operating around resonant frequencies, it is recommended to completely remove RSHUNT.
Transient analysis supply ramping time
Sets ramping time for capacitor and inductor code models.
s
CONVSTEP
Fractional step allowed by code model inputs between iterations
Controls automatic convergence assistance by establishing a relative step size limit in solving for the DC operating point.
CONVABSSTEP
Absolute step allowed by code model inputs between iterations
Controls automatic convergence assistance by establishing an absolute step size limit in solving for the DC operating point.
CONVLIMIT
Enables/disables a convergence algorithm used in some built-in component models.
ACCT
Turns on/off the display of statistical data on simulation-related information. Data may be useful for debugging simulation-related problems. Data appears in the Grapher.
RAWFILEFORMAT
Applies to the design on a per analysis basis. You cannot switch between ASCII and Binary modes globally.
Binary files are much smaller in size, resulting in faster performance, including post processing.
Multisim student activation code

An activation code will be read back to you over the phone. NI Multisim Crack + Activation Code. Free dora videos full episodes free. Ni Multisim Activation Code Crack DOWNLOAD d77fe87ee0 National Instruments Multisim v14 Download. Has ended message and a. Get started with NI Multisim This handy tutorial will help you download, install, and activate your circuit design. Under Multisim 14.0.1, right-click Schematic capture and simulation and select Activate. On the Activation Wizard box, select Automatically activate and then select Next. Input the serial number from page 1 and select Next.